官窑博士力士乐TDM3.2伺服驱动器D905故障维修
官窑博士力士乐TDM3.2伺服驱动器D905故障维修
力士乐伺服驱动器维修:故障解析:
D905故障含义:Wrong Position Range位置范围错误
Description:故障说明:
Before starting an automatic control loop setting, both travel range limits,
i.e., upper and lower, must be defined.在开始自动控制回路设置之前,两个行程范围限制,i、 e.必须定义上限和下限。
When starting command P-0-0162, D9 automatic control loop setting the number values are automatically checked for validity. It is checked if
the traversing path is large enough and if sensible values have been
entered.当启动命令P-0-0162、D9自动控制回路设置时,会自动检查数值的有效性。检查是否遍历路径足够大,并且如果合理的值进入。
报警故障代码维修:C0270 .C0285 .E2074 .F2076 .C0210 .C0220 .C0271 .C0201 .E8260 .F2026 .F2077 .F2816 .F2018 .F2019 .F2022 .F2820 .F2100 .F2074 .F2048 .F2008
Possible fault causes:可能的故障原因:
• P-0-0167, upper traversing range smaller than P-0-0166, lower
traversing rangeP-0-0167,上部横向范围小于P-0-0166,下部横向测量范围
• Maximum traversing path (= upper - lower limits) is less than 6 motor
rotations and thus too small to start the automatic control loop setting.大横移路径(=上限-下限)小于6个电机旋转,因此太小,无法启动自动控制回路设置。