力士乐DKC02.3-100-7-FW伺服驱动器F226报警维修小窍门

                             力士乐DKC02.3-100-7-FW伺服驱动器F226报警维修小窍门

力士乐驱动器报警代码

力士乐伺服驱动器维修技巧:故障解析:

E255 Feedrate-Override(S-0-0108) = 0

进给率超控(S-0-0108)=0

Description:故障描述:

The transversing velocity can be changed while jogging, homing and

while in positioning operation with the "S-0-0108, Feedrate Override"

parameter. Since the drive controller cannot follow command values

which do not move, the warning will be given if the value of this parameter

is 0.在慢跑、归位和在使用“S-0-0108,进给率超控”进行定位操作时参数由于驱动器控制器无法遵循命令值如果该参数的值为0。

Cause:原因:

1. Feedrate override is set at zero.

2. The "Feedrate Override Via Analog Output" field is activated and the voltage there is 0V.

3. Positioning speed = 0

1.进给速度超控设置为零。

2.“通过模拟输出的进给率覆盖”字段被激活,电压为0V。

3.定位速度=0

Remedy:解决措施:

1. Set the S-0-0108 parameter to the correct value for the application.

2. Deactivate the field or establish a voltage larger than 0V.

3. Positioning speed greater than 0 must be selected.

1.将S-0-0108参数设置为适用的正确值。

2.停用磁场或建立大于0V的电压。

3.必须选择大于0的定位速度。